1 month
the ceiling lights : 60W incandescent lamp x4 = 240W
average use time : 4 hours/day
Tokyo Denryoku:240Wx4hoursx30=28.8kWh 514yen/month
175yen 2000h life
if all replaced to fluorescent bulbs...
12Wx4=48W
average use time : 4hours/day
Tokyo Denryoku:5.76kWh=103yen
380yen 6000h life
if all replaced to LED bulbs...
7.5W x4 = 30W
average use time : 4hours
Tokyo Denryoku:64yen/month
3500yen 40000h life(SHARP)
1year
incandescent lamp:
514yen x 12 month = 6168 yen
4 hours x 360days / 2000h life = 0.72
0.72 x 4 = 2.88 bulbs cost 504 yen
TOTAL:6672yen
fluorescent lamp:
103 x 12 month = 1236yen
4 hours x 360days / 6000h life = 0.24
0.24 x 4 = 0.96 bulbs cost 364.8yen
TOTAL:1600yen
LED lamp:
64 x 12 = 768yen
4 hours x 360 days / 40000h life = 0.036
0.036 x 4 = 0.144 bulbs cost 504yen
TOTAL:1272yen